{"id":3271,"date":"2025-03-26T09:04:12","date_gmt":"2025-03-26T08:04:12","guid":{"rendered":"https:\/\/www.bq-microwave.de\/staging070225\/?p=3271"},"modified":"2025-04-07T15:28:59","modified_gmt":"2025-04-07T13:28:59","slug":"wr3-waveguide-power-detector-220-325-ghz","status":"publish","type":"post","link":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/","title":{"rendered":"WR3 Waveguide Power Detector 220-325 GHz"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container fusion-parallax-none nonhundred-percent-fullwidth non-hundred-percent-height-scrolling lazyload\" style=\"--awb-background-position:right top;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:-180px;--awb-min-height:1250px;--awb-background-size:cover;--awb-flex-wrap:wrap;\" data-bg=\"https:\/\/www.bq-microwave.de\/wp-content\/uploads\/2021\/02\/bq-microwaves_news_bg.png\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:calc( 1640px + 0px );margin-left: calc(-0px \/ 2 );margin-right: calc(-0px \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:100%;--awb-spacing-right-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-spacing-right-small:0px;--awb-spacing-left-small:0px;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-background-position:right top;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:-900px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:calc( 1640px + 0px );margin-left: calc(-0px \/ 2 );margin-right: calc(-0px \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:100%;--awb-spacing-right-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-spacing-right-small:0px;--awb-spacing-left-small:0px;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-one\"><h1 class=\"fusion-title-heading title-heading-left fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:40;line-height:1.5;\">WR3 Waveguide Detector 220-325 GHz<\/h1><\/div><div class=\"fusion-image-element\" style=\"--awb-margin-top:60px;--awb-margin-bottom:60px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\"fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" title=\"Cables Assemblies up to 110 GHz\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-orig-src=\"https:\/\/www.bq-microwave.de\/wp-content\/uploads\/2025\/03\/WR3-Waveguide-Power-Detector-220-325-GHz-1024x732.png\" alt class=\"lazyload img-responsive wp-image-2998\"\/><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_2_3 2_3 fusion-flex-column\" style=\"--awb-padding-top:40px;--awb-bg-size:cover;--awb-width-large:66.666666666667%;--awb-margin-top-large:0px;--awb-spacing-right-large:0px;--awb-margin-bottom-large:0px;--awb-spacing-left-large:0px;--awb-width-medium:66.666666666667%;--awb-order-medium:0;--awb-spacing-right-medium:0px;--awb-spacing-left-medium:0px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:0px;--awb-spacing-left-small:0px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><p><strong>AT-PD-220325 Waveguide Power Detector: High-Sensitivity Detection from 220GHz to 325GHz<\/strong><\/p>\n<p>In the rapidly evolving world of millimeter-wave and sub-terahertz applications, precise power detection is essential. The AT-PD-220325 from AT Microwave is a state-of-the-art positive slope power detector designed for high-frequency applications, covering the 220GHz to 325GHz range. With its high sensitivity and compact design, it is an excellent solution for engineers and researchers working in J-band imaging, radar systems, and RF over fiber (ROF) applications.<\/p>\n<p><strong>Key Features and Benefits<\/strong><\/p>\n<p><strong>Wide Frequency Range (220GHz &#8211; 325GHz)<\/strong><\/p>\n<ul>\n<li>The AT-PD-220325 operates within the WR-3.4 waveguide band, making it suitable for advanced high-frequency applications.<\/li>\n<\/ul>\n<p><strong>High Sensitivity for Small Signal Detection<\/strong><\/p>\n<ul>\n<li>With a sensitivity of 1500mV\/mW at an input power of -25dBm, this detector is ideal for low-power signal monitoring.<\/li>\n<\/ul>\n<p><strong>Broad Power Range (-30dBm to -5dBm)<\/strong><\/p>\n<ul>\n<li>Capable of detecting signals within a wide power range, the AT-PD-220325 ensures reliable performance in various testing and measurement scenarios.<\/li>\n<\/ul>\n<p><strong>No External Bias Required<\/strong><\/p>\n<ul>\n<li>Unlike many other high-frequency detectors, this model operates without requiring an external bias, simplifying integration and operation.<\/li>\n<\/ul>\n<p><strong>Compact and Durable Design<\/strong><\/p>\n<ul>\n<li>Housed in a gold-plated copper case, the AT-PD-220325 is not only robust but also ensures excellent signal integrity. It features a WR-3.4 waveguide input port and an SMA female IF output port for seamless connectivity.<\/li>\n<\/ul>\n<p><strong>Applications<\/strong><\/p>\n<ul data-spread=\"false\">\n<li>J-Band Imaging: Ideal for high-frequency imaging applications.<\/li>\n<li>Foreign Object Debris (FOD) Detection: Used in airport safety and industrial inspection systems.<\/li>\n<li>Test Equipment: A crucial component in RF and microwave testing setups.<\/li>\n<li>RF Over Fiber (ROF) Systems: Ensures precise power monitoring in fiber-based RF applications.<\/li>\n<li>Radar Systems: Supports advanced millimeter-wave radar technologies.<\/li>\n<\/ul>\n<p><strong>Technical Specifications at a Glance<\/strong><\/p>\n<ul data-spread=\"false\">\n<li>Frequency Range: 220GHz &#8211; 325GHz<\/li>\n<li>Sensitivity: 1500mV\/mW (at -25dBm input)<\/li>\n<li>Input Power Range: -30dBm to -5dBm<\/li>\n<li>Maximum Linearity Power: -5dBm<\/li>\n<li>Maximum Power Handling: +10dBm<\/li>\n<li>Output Voltage Polarity: Positive<\/li>\n<li>Operating Temperature: 0\u00b0C to 50\u00b0C<\/li>\n<\/ul>\n<p><strong>Why Choose the AT-PD-220325?<\/strong><\/p>\n<p>AT Microwave\u2019s AT-PD-220325 is an optimal choice for engineers and researchers requiring a reliable, high-sensitivity waveguide power detector. Its broad frequency range, compact size, and excellent performance make it a must-have component in high-frequency detection applications.<\/p>\n<p><strong>Find Out More<\/strong><\/p>\n<p>For more details, specifications, or purchasing information, visit <a href=\"http:\/\/www.atmicrowave.com\/\"><strong>AT Microwave\u2019s website<\/strong><\/a> or contact bq-microwave, your trusted European distributor for AT Microwave products.<\/p>\n<p>Stay ahead in the high-frequency domain with AT Microwave\u2019s industry-leading waveguide solutions!<\/p>\n<\/div><div ><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-1 fusion-button-default-span fusion-button-default-type\" target=\"_self\" href=\"https:\/\/www.bq-microwave.de\/wp-content\/uploads\/2025\/03\/WR3-Waveguide-Detector-220-325-GHz-www.bq-microwave.de_.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">Download all info as PDF<\/span><\/a><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1705.6px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><\/div><\/div><\/p>","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":3272,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3271","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>WR3 Waveguide Power Detector 220-325 GHz - BQ Microwave<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"WR3 Waveguide Power Detector 220-325 GHz - BQ Microwave\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/\" \/>\n<meta property=\"og:site_name\" content=\"BQ Microwave\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-26T08:04:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-07T13:28:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.bq-microwave.de\/wp-content\/uploads\/2025\/04\/WR3-Waveguide-Power-Detector-220-325-GHz.png\" \/>\n\t<meta property=\"og:image:width\" content=\"2017\" \/>\n\t<meta property=\"og:image:height\" content=\"1442\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Marcel Volm\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marcel Volm\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/\"},\"author\":{\"name\":\"Marcel Volm\",\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/#\\\/schema\\\/person\\\/154a687f83bea831e67f57e3c7e4758e\"},\"headline\":\"WR3 Waveguide Power Detector 220-325 GHz\",\"datePublished\":\"2025-03-26T08:04:12+00:00\",\"dateModified\":\"2025-04-07T13:28:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/\"},\"wordCount\":1870,\"image\":{\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bq-microwave.de\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/WR3-Waveguide-Power-Detector-220-325-GHz.png\",\"articleSection\":[\"News\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/\",\"url\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/\",\"name\":\"WR3 Waveguide Power Detector 220-325 GHz - BQ Microwave\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bq-microwave.de\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/WR3-Waveguide-Power-Detector-220-325-GHz.png\",\"datePublished\":\"2025-03-26T08:04:12+00:00\",\"dateModified\":\"2025-04-07T13:28:59+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/#\\\/schema\\\/person\\\/154a687f83bea831e67f57e3c7e4758e\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.bq-microwave.de\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/WR3-Waveguide-Power-Detector-220-325-GHz.png\",\"contentUrl\":\"https:\\\/\\\/www.bq-microwave.de\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/WR3-Waveguide-Power-Detector-220-325-GHz.png\",\"width\":2017,\"height\":1442},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/news\\\/wr3-waveguide-power-detector-220-325-ghz\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.bq-microwave.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"WR3 Waveguide Power Detector 220-325 GHz\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/\",\"name\":\"BQ Microwave\",\"description\":\"Hochfrequenz\u2013 und Millimeterwellen-Komponenten\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/#\\\/schema\\\/person\\\/154a687f83bea831e67f57e3c7e4758e\",\"name\":\"Marcel Volm\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/779e1b200e4ba4d1b0932a17ec2b3da28d43bd1e4fb4e51473d616015c19fd76?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/779e1b200e4ba4d1b0932a17ec2b3da28d43bd1e4fb4e51473d616015c19fd76?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/779e1b200e4ba4d1b0932a17ec2b3da28d43bd1e4fb4e51473d616015c19fd76?s=96&d=mm&r=g\",\"caption\":\"Marcel Volm\"},\"url\":\"https:\\\/\\\/www.bq-microwave.de\\\/en\\\/author\\\/mvolm\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"WR3 Waveguide Power Detector 220-325 GHz - BQ Microwave","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/","og_locale":"en_US","og_type":"article","og_title":"WR3 Waveguide Power Detector 220-325 GHz - BQ Microwave","og_url":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/","og_site_name":"BQ Microwave","article_published_time":"2025-03-26T08:04:12+00:00","article_modified_time":"2025-04-07T13:28:59+00:00","og_image":[{"width":2017,"height":1442,"url":"https:\/\/www.bq-microwave.de\/wp-content\/uploads\/2025\/04\/WR3-Waveguide-Power-Detector-220-325-GHz.png","type":"image\/png"}],"author":"Marcel Volm","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Marcel Volm","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/#article","isPartOf":{"@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/"},"author":{"name":"Marcel Volm","@id":"https:\/\/www.bq-microwave.de\/en\/#\/schema\/person\/154a687f83bea831e67f57e3c7e4758e"},"headline":"WR3 Waveguide Power Detector 220-325 GHz","datePublished":"2025-03-26T08:04:12+00:00","dateModified":"2025-04-07T13:28:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/"},"wordCount":1870,"image":{"@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bq-microwave.de\/wp-content\/uploads\/2025\/04\/WR3-Waveguide-Power-Detector-220-325-GHz.png","articleSection":["News"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/","url":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/","name":"WR3 Waveguide Power Detector 220-325 GHz - BQ Microwave","isPartOf":{"@id":"https:\/\/www.bq-microwave.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/#primaryimage"},"image":{"@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bq-microwave.de\/wp-content\/uploads\/2025\/04\/WR3-Waveguide-Power-Detector-220-325-GHz.png","datePublished":"2025-03-26T08:04:12+00:00","dateModified":"2025-04-07T13:28:59+00:00","author":{"@id":"https:\/\/www.bq-microwave.de\/en\/#\/schema\/person\/154a687f83bea831e67f57e3c7e4758e"},"breadcrumb":{"@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/#primaryimage","url":"https:\/\/www.bq-microwave.de\/wp-content\/uploads\/2025\/04\/WR3-Waveguide-Power-Detector-220-325-GHz.png","contentUrl":"https:\/\/www.bq-microwave.de\/wp-content\/uploads\/2025\/04\/WR3-Waveguide-Power-Detector-220-325-GHz.png","width":2017,"height":1442},{"@type":"BreadcrumbList","@id":"https:\/\/www.bq-microwave.de\/en\/news\/wr3-waveguide-power-detector-220-325-ghz\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.bq-microwave.de\/"},{"@type":"ListItem","position":2,"name":"WR3 Waveguide Power Detector 220-325 GHz"}]},{"@type":"WebSite","@id":"https:\/\/www.bq-microwave.de\/en\/#website","url":"https:\/\/www.bq-microwave.de\/en\/","name":"BQ Microwave","description":"Hochfrequenz\u2013 und Millimeterwellen-Komponenten","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bq-microwave.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.bq-microwave.de\/en\/#\/schema\/person\/154a687f83bea831e67f57e3c7e4758e","name":"Marcel Volm","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/779e1b200e4ba4d1b0932a17ec2b3da28d43bd1e4fb4e51473d616015c19fd76?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/779e1b200e4ba4d1b0932a17ec2b3da28d43bd1e4fb4e51473d616015c19fd76?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/779e1b200e4ba4d1b0932a17ec2b3da28d43bd1e4fb4e51473d616015c19fd76?s=96&d=mm&r=g","caption":"Marcel Volm"},"url":"https:\/\/www.bq-microwave.de\/en\/author\/mvolm\/"}]}},"_links":{"self":[{"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/posts\/3271","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/comments?post=3271"}],"version-history":[{"count":1,"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/posts\/3271\/revisions"}],"predecessor-version":[{"id":3273,"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/posts\/3271\/revisions\/3273"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/media\/3272"}],"wp:attachment":[{"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/media?parent=3271"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/categories?post=3271"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bq-microwave.de\/en\/wp-json\/wp\/v2\/tags?post=3271"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}